Pepperl + Fuchs SC-System signal conditioners are especially designed for general purpose applications and ensure reliable process communication. High-quality isolation, an extended temperature range, and an extremely compact housing design characterise the signal conditioner range.
Stock: 2 available
Categories: SPLITTERS, CONVERTERS & ISOLATORS
| General specifications | |
| Signal type | Analog input |
| Operation time | MTBF: 353 a acc. to SN 29500 stationary continuous operating, average ambient temperature 40 °C (104 °F) |
| Supply | |
| Connection | Power Bus or terminals 1-, 2+ |
| Rated voltage | 16.8 … 31.2 V DC |
| Power dissipation | 0.7 W |
| Power consumption | 0.8 W |
| Interface | |
| Programming interface | programming socket |
| Input | |
| Connection side | field side |
| Connection | terminals 5, 6, 7, 8 |
| PTC | type KT, KTY, ST |
| Measuring current | approx. 200 µA |
| Types of measuring | 2-, 3-, 4-wire connection |
| Lead resistance | ≤ 100 Ω per line |
| Measurement loop monitoring | sensor breakage, lead breakage, short circuit |
| RTD | type Pt100, Pt200, Pt500, Pt1000 (EN 60751:1995) type Ni100, Ni200, Ni500, Ni1000 (DIN 43760) |
| Measuring current | approx. 200 µA |
| Types of measuring | 2-, 3-, 4-wire connection |
| Lead resistance | max. 100 Ω per line |
| Measurement loop monitoring | sensor breakage, lead breakage, short circuit |
| Thermocouples | type B, E, J, K, N, S, T (IEC 584-1:1995) type L, U (DIN 43710:1985) type C, D (ASTM E988) |
| Cold junction compensation | external (Pt100) and internal , manually |
| Lead resistance | max. 10 kΩ |
| Measurement loop monitoring | sensor breakage, lead breakage |
| Resistor | |
| Measuring range | 0 … 5 kΩ |
| Potentiometer | 0.2 … 50 kΩ |
| Types of measuring | 3-wire connection |
| Voltage | -100 … 100 mV
-1000 … 1000 mV |
| Input resistance | ≥ 1 MΩ |
| Output | |
| Connection side | control side |
| Connection | terminals 3-, 4+ |
| Analog voltage output | 0/1 … 5 V , 0/2 … 10 V , load ≥ 2 kΩ |
| Analog current output | 0/2 … 10 mA, 0/4 … 20 mA, load ≤ 600 Ω |
| Ripple | ≤ 10 mV eff |
| Fault signal | downscale or upscale |
| Transfer characteristics | |
| Accuracy | max. 0.1 % of full-scale value |
| Measuring time | ≤ 300 ms |
| Deviation | |
| RTD | < 0.1 K/0.05 % of the measured value |
| Thermocouples | < 0.3 K/0.1 % of the measured value |
| Voltage | < 0.1 % of the measured value |
| Potentiometer | < 0.02 % of the measured value |
| Influence of ambient temperature | < 100 ppm/K of full-scale value |
| Galvanic isolation | |
| Output/power supply | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min |
| Input/Other circuits | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min |
| Indicators/settings | |
| Control elements | DIP switch
keys |
| Configuration | via DIP switches
via keys via software |
| Labeling | space for labeling at the front |
| Directive conformity | |
| Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Conformity | |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | EN 61010-1:2010 |
| Ambient conditions | |
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Mechanical specifications | |
| Degree of protection | IP20 |
| Connection | screw terminals |
| Core cross section | 0.5 … 2.5 mm2 (20 … 14 AWG) |
| Mass | approx. 70 g |
| Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1 |
| Height | 97 mm |
| Width | 6.2 mm |
| Depth | 107 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |