DFM INDUSTRIAL FLOW METER
October 21, 2025
LC RING LIQUID COUNTER
October 22, 2025LC Gear liquid counters are used for measuring consumption of light petroleum products, primarily diesel fuel (including marine diesel), heating oil, and non-agressive fuel additives.
The LC Gear series counters are use for metering total consumption of liquid fuel, recording total operating time of the flow, measuring volumes of dispensed liquids.
Stock: available
Application of the LC Gear Liquid Counter:
- High-power diesel gensets, heaters
- Fuel delivery trucks and fuel tankers
- Petrochemical production
- Power generation units of ferries, tugs, medium-size ships
- Power generation units of railway equipment
- Fuel transfer and dispensing systems (fuel stations)
Design advantages:
1)Measuring chamber with oval gearsHigh measurement accuracy across a wide range of viscosities
2)Informative digital displayOver 15 operating counters, local data monitoring
3)Built-in batteryAutonomous operation and data storage without external power
4)Variety of interfacesCAN J1939, pulse, Bluetooth Low Energy
Specifications:
| Model | LC Gear 120 | LC Gear 410 |
|---|---|---|
| Minimum liquid flow rate, L/min | 12 | 41 |
| Maximum liquid flow rate, L/min | 120 | 416 |
| Relative error, max, % | 0,25 | |
| Viscosity of the working liquid, mm²/s (cSt) | from 0.5 to 30 (calibrated at production) | |
| Maximum working liquid temperature, °C | 90 | |
| Maximum working liquid pressure, Mpa | 1,6 | |
| Interfaces | CAN j1939, pulse, RS-485 (optional converter) | |
| Ingress protection rating | IP 68 | |
| Types of connection | flanged, threaded | flanged |
| Weight, not more than, kg | 5,4 | 14,6 |
Data on display and in output interface:
- Total liquid consumption
- Total operating time of counter
- Liquid consumption by operating modes
- Counter operating time by modes
- Liquid consumption (clearable)
- Counter operating time (clearable)
- Temperature in measuring chamber